Home >> Professional >> Rad-tolerant parts
As information on how electronic components support radiation is very rare, here I provide data which would be very useful for me as well.
Below is a list of components which I have used in my larger projects, where significant part of the electronics had to be put close to the beam pipe and therefore exposed to an important radiation.
The doses provided, if not otherwise stated, have not had a significant influence on the part functionality.
The doses in most cases are based on rough estimates and therefore should be used as an indication only.

Publication of my part list has been encouraged by Tullio, who on his site publishes a lot of very valuable information, including a literature list.

Useful links to information on radiation tolerance of electronic components:

Marek's list of radiation-tolerant parts as a PDF file.
Marek's list of radiation-tolerant parts as an Excel file.


 
PLEASE NOTE:	1. This data is provided only as an INDICATION of radiation sensitivity of components I used in some of my projects.
		   In most cases the data is based on ROUGH ESTIMATES.
		2. A component from a different manufacturer or batch, operated in different conditions may tolerate radiation differently.  
		3. If not stated otherwise, the integrated doses indicated below did not have significant influence on part functionality.


project number                  1               2               3               4

facility 			CTF3 		SPS             LHC 		LHC
project                         BPM head amp    BBQ front-end   BBQ front-end   BQK driver proto
position w.r.t. ground [m]      0.3             0.3             0.3             0.3
position w.r.t. beam pipe [m]   1.0             1.0             1.0             1.0
species                         electrons       protons         protons         protons
energy                          1-150 MeV       26-450 GeV      0.45-4 TeV      0.45-4 TeV
time of operation [years]       8               5               3               2
number of units                 50              3               6               1
estimated dose per year [Gy]    1000            100             50              50
integrated dose [Gy]            10000           500             200             100              


part                    int. dose [Gy]          project #               function, comments

LM2940-05               8000                    1                       LDO regulator, 1 A, 5 V
LM2990-05               8000                    1                       LDO, 1 A, -5 V
AD8009                  8000                    1                       op-amp, current FB
AD8129                  8000                    1                       differential amp
AD8170                  8000                    1                       buffered analog mux

LM2941                  500                     2, 3                    LDO adjustable, 1A, operated at 15 V
LM2991                  500                     2, 3                    LDO adjustable, 1A, operated at 15 V
OPA627                  500                     2, 3                    op-amp, J-FET, precision
OPA227                  500                     2, 3                    op-amp, precision, low noise
AD825                   500                     2, 3                    op-amp, J-FET, precision
THS3041                 500                     2, 3                    op-amp
BSR17                   500                     2, 3                    NPN RF transistor
BSR18                   500                     2, 3                    PNP RF transistor
CD40244                 500                     2, 3                    CMOS logic, operated at 15 V
CD4556                  500                     2, 3                    CMOS logic, operated at 15 V
HSMS280C                500                     2, 3                    RF Schottky diode

OPA827                  150                     3                       op-amp, J-FET, low noise

TXL 025-3.3S            100                     4                       switching power supply, 3.3 V, 25 W, TracoPower
LT1764                  100                     4                       LDO adjustable, 3 A, operated at 2.5 V

TXL 025-24S 		100-1000 		R&D 			switching power supply, 24 V, 25 W, TracoPower          
									2 pieces broken down in the LHC tunnel at point 5 (for 2 pieces installed)     	
									radiation damage to controller NCP1203			